CVEMETERBack to radar
OFFICIAL RECORD · C/C++ libraries

CVE-2025-0665

PUBLISHEDOfficial status check: verifiedCVSS 3.1: 7 · high

eventfd double close

libcurl would wrongly close the same eventfd file descriptor twice when taking down a connection channel after having completed a threaded name resolve.

Exposure status: unknown. This page does not establish whether an installed system is affected or corrected.

Severity and exploitation evidence

EPSS: 1.322% · score date 2026-11-19. EPSS is an estimated probability over the next 30 days, not proof of exploitation.

CISA KEV: not included in the checked catalog; exploitation may still occur. Last checked: 2026-11-19T16:57:41.748Z. Public exploit availability is not used to set this status.

CVSS 3.1 · 7 · published by 134c704f-9b21-4f2e-91b3-4a467353bcc0
CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:H
Assessment source · checked 2026-11-19T12:42:21.483Z

Verification by field

FieldStatusChecked at (UTC)Source
kevverified2026-11-19T16:57:41.748ZCISA KEV
cvssverified2026-11-19T12:42:21.483ZNVD
epssverified2026-11-19T16:04:39.514ZFIRST EPSS
patchesunknownunknownunknown
affectedverified2026-11-19T12:57:23.626ZCVE Program
lifecycleverified2026-11-19T12:57:23.626ZCVE Program

Affected versions and configuration

curl curl; default status: unaffected: 8.11.1 to ≤ 8.11.1 [affected; scheme: semver]

Defaults, conditional configuration, package status and version schemes are retained below. A version range alone is not an exposure verdict.

CVE Program · cve-json · full conditions
{
  "affected": [
    {
      "vendor": "curl",
      "product": "curl",
      "versions": [
        {
          "status": "affected",
          "version": "8.11.1",
          "versionType": "semver",
          "lessThanOrEqual": "8.11.1"
        }
      ],
      "defaultStatus": "unaffected"
    }
  ],
  "additionalContainers": [
    {
      "title": "CVE Program Container",
      "references": [
        {
          "url": "http://www.openwall.com/lists/oss-security/2025/02/05/2"
        },
        {
          "url": "http://www.openwall.com/lists/oss-security/2025/02/05/5"
        },
        {
          "url": "https://security.netapp.com/advisory/ntap-20250306-0007/"
        }
      ],
      "providerMetadata": {
        "orgId": "af854a3a-2127-422b-91ae-364da2661108",
        "shortName": "CVE",
        "dateUpdated": "2025-03-07T00:10:49.291Z"
      }
    },
    {
      "title": "CISA ADP Vulnrichment",
      "metrics": [
        {
          "cvssV3_1": {
            "scope": "UNCHANGED",
            "version": "3.1",
            "baseScore": 7,
            "attackVector": "NETWORK",
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:H",
            "integrityImpact": "LOW",
            "userInteraction": "NONE",
            "attackComplexity": "HIGH",
            "availabilityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "confidentialityImpact": "LOW"
          }
        },
        {
          "other": {
            "type": "ssvc",
            "content": {
              "id": "CVE-2025-0665",
              "role": "CISA Coordinator",
              "options": [
                {
                  "Exploitation": "none"
                },
                {
                  "Automatable": "no"
                },
                {
                  "Technical Impact": "partial"
                }
              ],
              "version": "2.0.3",
              "timestamp": "2026-03-17T17:42:03.317434Z"
            }
          }
        }
      ],
      "providerMetadata": {
        "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "shortName": "CISA-ADP",
        "dateUpdated": "2026-03-17T17:42:06.679Z"
      }
    },
    {
      "affected": [
        {
          "vendor": "Siemens",
          "product": "RUGGEDCOM RST2428P",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V3.3",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SCALANCE XC-300/XR-300/XC-400/XR-500WG/XR-500 family",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V3.3",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SCALANCE XCH328",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V3.3",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SCALANCE XCM324",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V3.3",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SCALANCE XCM328",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V3.3",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SCALANCE XCM332",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V3.3",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SCALANCE XRH334 (24 V DC, 8xFO, CC)",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V3.3",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SCALANCE XRM334 (230 V AC, 12xFO)",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V3.3",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SCALANCE XRM334 (230 V AC, 8xFO)",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V3.3",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SCALANCE XRM334 (230V AC, 2x10G, 24xSFP, 8xSFP+)",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V3.3",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SCALANCE XRM334 (24 V DC, 12xFO)",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V3.3",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SCALANCE XRM334 (24 V DC, 8xFO)",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V3.3",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SCALANCE XRM334 (24V DC, 2x10G, 24xSFP, 8xSFP+)",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V3.3",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SCALANCE XRM334 (2x230 V AC, 12xFO)",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V3.3",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SCALANCE XRM334 (2x230 V AC, 8xFO)",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V3.3",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SCALANCE XRM334 (2x230V AC, 2x10G, 24xSFP, 8xSFP+)",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V3.3",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC S7-1500 CPU 1518-4 PN/DP MFP",
          "versions": [
            {
              "status": "affected",
              "version": "V3.1.0",
              "lessThan": "V3.1.5",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC S7-1500 CPU 1518-4 PN/DP MFP",
          "versions": [
            {
              "status": "affected",
              "version": "V3.1.0",
              "lessThan": "V3.1.5",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP",
          "versions": [
            {
              "status": "affected",
              "version": "V3.1.0",
              "lessThan": "V3.1.5",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP",
          "versions": [
            {
              "status": "affected",
              "version": "V3.1.0",
              "lessThan": "V3.1.5",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIPLUS S7-1500 CPU 1518-4 PN/DP MFP",
          "versions": [
            {
              "status": "affected",
              "version": "V3.1.0",
              "lessThan": "V3.1.5",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        }
      ],
      "x_adpType": "supplier",
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-398330.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-089022.html"
        }
      ],
      "providerMetadata": {
        "orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
        "shortName": "siemens-SADP",
        "dateUpdated": "2026-10-15T01:01:54.492Z"
      }
    }
  ]
}
Archived source JSON
NVD · nvd-cpe · full conditions
[
  {
    "nodes": [
      {
        "negate": false,
        "cpeMatch": [
          {
            "criteria": "cpe:2.3:a:haxx:curl:8.11.1:*:*:*:*:*:*:*",
            "vulnerable": true,
            "matchCriteriaId": "AC5F2B81-22E8-4A24-B4AA-86FC581E95D9"
          }
        ],
        "operator": "OR"
      }
    ]
  },
  {
    "nodes": [
      {
        "negate": false,
        "cpeMatch": [
          {
            "criteria": "cpe:2.3:o:netapp:bootstrap_os:-:*:*:*:*:*:*:*",
            "vulnerable": true,
            "matchCriteriaId": "95BA156C-C977-4F0C-8DFB-3FAE9CC8C02D"
          }
        ],
        "operator": "OR"
      },
      {
        "negate": false,
        "cpeMatch": [
          {
            "criteria": "cpe:2.3:h:netapp:hci_compute_node:-:*:*:*:*:*:*:*",
            "vulnerable": false,
            "matchCriteriaId": "AD7447BC-F315-4298-A822-549942FC118B"
          }
        ],
        "operator": "OR"
      }
    ],
    "operator": "AND"
  },
  {
    "nodes": [
      {
        "negate": false,
        "cpeMatch": [
          {
            "criteria": "cpe:2.3:o:netapp:h300s_firmware:-:*:*:*:*:*:*:*",
            "vulnerable": true,
            "matchCriteriaId": "6770B6C3-732E-4E22-BF1C-2D2FD610061C"
          }
        ],
        "operator": "OR"
      },
      {
        "negate": false,
        "cpeMatch": [
          {
            "criteria": "cpe:2.3:h:netapp:h300s:-:*:*:*:*:*:*:*",
            "vulnerable": false,
            "matchCriteriaId": "9F9C8C20-42EB-4AB5-BD97-212DEB070C43"
          }
        ],
        "operator": "OR"
      }
    ],
    "operator": "AND"
  },
  {
    "nodes": [
      {
        "negate": false,
        "cpeMatch": [
          {
            "criteria": "cpe:2.3:o:netapp:h410c_firmware:-:*:*:*:*:*:*:*",
            "vulnerable": true,
            "matchCriteriaId": "234DEFE0-5CE5-4B0A-96B8-5D227CB8ED31"
          }
        ],
        "operator": "OR"
      },
      {
        "negate": false,
        "cpeMatch": [
          {
            "criteria": "cpe:2.3:h:netapp:h410c:-:*:*:*:*:*:*:*",
            "vulnerable": false,
            "matchCriteriaId": "CDDF61B7-EC5C-467C-B710-B89F502CD04F"
          }
        ],
        "operator": "OR"
      }
    ],
    "operator": "AND"
  },
  {
    "nodes": [
      {
        "negate": false,
        "cpeMatch": [
          {
            "criteria": "cpe:2.3:o:netapp:h410s_firmware:-:*:*:*:*:*:*:*",
            "vulnerable": true,
            "matchCriteriaId": "D0B4AD8A-F172-4558-AEC6-FF424BA2D912"
          }
        ],
        "operator": "OR"
      },
      {
        "negate": false,
        "cpeMatch": [
          {
            "criteria": "cpe:2.3:h:netapp:h410s:-:*:*:*:*:*:*:*",
            "vulnerable": false,
            "matchCriteriaId": "8497A4C9-8474-4A62-8331-3FE862ED4098"
          }
        ],
        "operator": "OR"
      }
    ],
    "operator": "AND"
  },
  {
    "nodes": [
      {
        "negate": false,
        "cpeMatch": [
          {
            "criteria": "cpe:2.3:o:netapp:h500s_firmware:-:*:*:*:*:*:*:*",
            "vulnerable": true,
            "matchCriteriaId": "7FFF7106-ED78-49BA-9EC5-B889E3685D53"
          }
        ],
        "operator": "OR"
      },
      {
        "negate": false,
        "cpeMatch": [
          {
            "criteria": "cpe:2.3:h:netapp:h500s:-:*:*:*:*:*:*:*",
            "vulnerable": false,
            "matchCriteriaId": "E63D8B0F-006E-4801-BF9D-1C001BBFB4F9"
          }
        ],
        "operator": "OR"
      }
    ],
    "operator": "AND"
  },
  {
    "nodes": [
      {
        "negate": false,
        "cpeMatch": [
          {
            "criteria": "cpe:2.3:o:netapp:h700s_firmware:-:*:*:*:*:*:*:*",
            "vulnerable": true,
            "matchCriteriaId": "56409CEC-5A1E-4450-AA42-641E459CC2AF"
          }
        ],
        "operator": "OR"
      },
      {
        "negate": false,
        "cpeMatch": [
          {
            "criteria": "cpe:2.3:h:netapp:h700s:-:*:*:*:*:*:*:*",
            "vulnerable": false,
            "matchCriteriaId": "B06F4839-D16A-4A61-9BB5-55B13F41E47F"
          }
        ],
        "operator": "OR"
      }
    ],
    "operator": "AND"
  }
]
Archived source JSON

Correction evidence

Distribution packages and upstream releases are distinct. ESM channels may require the corresponding Ubuntu entitlement. Notes and branch ranges are not installable package versions. OSV fixed boundaries are ecosystem-specific version thresholds, not proof that a package is currently available or installed.

No correction has been verified in the connected records. This does not mean the system is secure or that no vendor correction exists.

Vendor notices and operational guidance

No connected vendor notice is available for this record.

Original sources and dates

Official status history